New 2022 Guaranteed Success with TestPassKing DES-1111 Dumps EMC PDF Questions [Q26-Q49]

Share

New 2022 Guaranteed Success with TestPassKing DES-1111 Dumps EMC PDF Questions

Exceptional Practice To Specialist - Technology Architect, PowerMax and VMAX All Flash Solutions Exam Pass the First Time


Certification Topics of Dell DES-1111 Exam

  • PowerMax and VMAX All Flash Features (20%)

  • Design and Sizing for PowerMax and VMAX All Flash (30%)

  • Virtualized Environments (10%)

  • Replication (20%)


What is Dell DES-1111 Exam

The Associate - Information Storage and Management Version 4.0 Exam is the qualifying exam for the Specialist - Technology Architect, PowerMax, and VMAX All Flash Solutions Specialist (DCS-TA) track. The Associate - Information Storage and Management Version 4.0 Exam validates that candidates have the knowledge to address general storage requirements and concepts, including provisioning storage in a data center environment, understanding RAID technology, the configuration of network connectivity for iSCSI and FC SANs, basic backup concepts and methodology, as well as an understanding of object storage concepts. Dell DES-1111 Dumps will help you prepare and pass the exam on the first attempt. We don't provide vce files to customer in our premium and demo versions package. Our subjects experts staff update the prep questions, and we Assured customers get unique success rate and get dream certification. We have a free demo PDF for education.


EMC DES-1111 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Perform TimeFinder SnapVX operations using management tools
  • Create PowerMax and VMAX All Flash sizing and upgrade solutions with VMAX Sizer
Topic 2
  • Describe architecture and key features of Unisphere for PowerMax
  • Overcoming business continuity business challenges
Topic 3
  • Identify PowerMax and VMAX All Flash management tools
  • Monitor PowerMax and VMAX All Flash SRPs, compliance, and data reduction
Topic 4
  • Perform Workload Planning activities with Unisphere for PowerMax
  • Describe Remote Replication Network Connectivity options
Topic 5
  • Provide overview and data collection techniques for BCSD
  • SRDF
  • S architecture and design considerations
Topic 6
  • Perform administrative tasks using Unisphere for PowerMax
  • Compare and contrast PowerMax and VMAX All Flash models
Topic 7
  • Key considerations for implementing PowerMax and VMAX All Flash in virtualized environments
  • Position PowerMax and VMAX All Flash solutions
Topic 8
  • Explain Virtual Provisioning concepts
  • RDF
  • A architecture and design considerations

 

NEW QUESTION 26
Refer to the exhibit.

This performance data is an example of what of output?

  • A. ESXTOP
  • B. SAR
  • C. IOSTAT
  • D. PERFMON

Answer: D

 

NEW QUESTION 27
An architect is collecting data from a Windows host to model a solution in BCSD. What is the correct sequence of steps to take so that BCSD can parse the data?

Answer:

Explanation:

 

NEW QUESTION 28
At a disaster planning meeting, an architect is presented with the following facts by a client:
A Unix host is replicating storage from a Production PowerMax to a VMAX 250FX.
RDF pairs have been split with Production and DR hosts accessing their respective storage.
Invalid tracks have started to build against PowerMax and VMAX 250FX.
The client now wants to bring production back to PowerMax, discarding the VMAX 250FX updates while keeping the updates on the PowerMax. What is the correct action to take?

  • A. Resume
  • B. Failover
  • C. Establish
  • D. Failback

Answer: D

 

NEW QUESTION 29
Where is the Unisphere performance database backup file stored on the Unisphere server host?

  • A. \SYMAP\backup\SPA
  • B. \Program Files\EMC\backup
  • C. \SMAS\backup\SPA
  • D. \SMAS\backup\data

Answer: C

 

NEW QUESTION 30
A storage administrator is unable to terminate the TimeFinder SnapVX snapshot. What action should be performed by the administrator?

  • A. Modify the Time to Live setting
  • B. Run a terminate command for each individual LUN
  • C. Verify that there are no linked targets or restore sessions
  • D. Check if there is an available reserved capacity

Answer: C

 

NEW QUESTION 31
What is the default data collection interval for TTP collections?

  • A. 30 minutes
  • B. 15 minutes
  • C. 5 minutes
  • D. 10 minutes

Answer: B

 

NEW QUESTION 32
A TimeFinder SnapVX snapshot of source volumes is linked to target volumes. The target volumes are being used for application testing.
What is recommended prior to a relink operation?

  • A. Stop accessing the source volumes; continue accessing the target volumes
  • B. Continue accessing both the source volumes and the target volumes
  • C. Continue accessing the source volumes; stop accessing the target volumes
  • D. Stop accessing both the source volumes and the target volumes

Answer: B

 

NEW QUESTION 33
How do Copy mode linked targets and NoCopy mode linked targets behave when a SnapVX unlink operation disassociates the linked target?

  • A. Once the copy completes, Copy mode linked targets do not contain a full and usable copy of the source devices.
    Behavior of NoCopy mode linked targets depends on the operating system running on the array. PowerMaxOS 5978 and HYPERMAX OS 5977.810.184 and later allow access to unlinked targets.
  • B. Once the copy completes, Copy mode linked targets contain a full and usable copy of the source devices.
    Behavior of NoCopy mode linked targets depends on the operating system running on the array. PowerMaxOS 5978 and HYPERMAX OS 5977.810.184 and later allow access to unlinked targets.
  • C. Once the copy completes, Copy mode linked targets contain a full and usable copy of the source devices.
    Behavior of NoCopy mode linked targets depends on the operating system running on the array. PowerMaxOS 5978 and HYPERMAX OS 5977.596.583 and later allow access to unlinked targets.
  • D. Once the copy completes, Copy mode linked targets will contain a full and usable copy of the source devices.NoCopy mode linked targets will not allow access to unlinked targets.

Answer: C

 

NEW QUESTION 34
An architect is configuring BCSD to design SRDF/S between two new PowerMax arrays. The architect has completed the tasks for the local side of the solution, including RA Port Group, Replication Group, and site switch.
What is the correct order of steps the architect needs to take to complete the SRDF setup?

Answer:

Explanation:

 

NEW QUESTION 35
The SecurityAdmin for Unisphere wants to create a new user that will perform all management (active or control) operations on a storage system and be able to modify GNS group definitions in addition to all Monitor operations. The user will not be able to create or delete user accounts.
What role needs to be assigned to the new user?

  • A. StorageAdmin
  • B. Device Management
  • C. SecurityAdmin
  • D. Admin

Answer: A

 

NEW QUESTION 36
When implementing SRDF/Metro with Array Witness, what is a requirement of the witness array?

  • A. Minimum of two witness arrays
  • B. Empty RDF group from witness to source and target
  • C. vApp running on a VMware ESXi server
  • D. Two RDF groups with source and target devices

Answer: D

 

NEW QUESTION 37
A storage architect is designing a PowerMax solution. The architect must ensure that the Unisphere server is not directly connected to the arrays.
Which type of Unisphere for PowerMax deployment will achieve the design requirements?

  • A. CloudIQ
  • B. eManagement
  • C. Remote Configuration
  • D. Local Configuration

Answer: A

 

NEW QUESTION 38
The output file of a Linux Host Collection Utility does not match the BCSD parser format. What could be the reason?

  • A. Incorrect LUNs specified
  • B. Perform is not up to date
  • C. OS patches are not up to date
  • D. BSCD is incorrectly configured

Answer: C

 

NEW QUESTION 39
A data migration is being planned from a Hitachi to a PowerMax using Open Replicator. Which flag is used to protect against SAN failure?

  • A. Hot Push
  • B. Donor Update
  • C. Copy on Access
  • D. Background Copy

Answer: A

 

NEW QUESTION 40
What is required before a port can be disassociated from an FA emulation on a PowerMax?

  • A. The port must not be a member of any Port Group
  • B. The port must not belong to an RDF group
  • C. All ports associated with the FA emulation must be offline
  • D. All ports on the I/O module must be offline

Answer: C

 

NEW QUESTION 41
Match each SRDF command with its function.

Answer:

Explanation:

 

NEW QUESTION 42
What is the best practice sizing guideline for front-end FA utilization on a single engine PowerMax array?

  • A. 0.6
  • B. 0.8
  • C. 0.7
  • D. 0.5

Answer: D

 

NEW QUESTION 43
Refer to the exhibit.

An SRDF/A solution with BCSD is designed and the results are shown in the exhibit. A customer requirement was a five-minute RPO. In the exhibit shown, the RPO is above the customer requirement.
How can the five-minute RPO requirement be met?

  • A. Provide more bandwidth
  • B. Increase cycle time
  • C. Increase DSE capacity
  • D. Increase number of RA ports

Answer: D

 

NEW QUESTION 44
A customer is planning to purchase a PowerMax 8000 system with the zEssentials software package. The environment needs to have the ability to rapidly recover from large scale logical corruption using TimeFinder SnapVX.
Which optional software should be recommended to fulfill the requirement?

  • A. Product Suite for z/TPF
  • B. AutoSwap
  • C. GDPR
  • D. zDP

Answer: D

 

NEW QUESTION 45
The Reserved Capacity for a Storage Resource Pool (SRP) on a VMAX All Flash array is set to 15%. A TimeFinder SnapVX snapshot is created for a Storage Group containing 10 devices. An application is actively performing read and write I/O to these devices. Allocation for the SRP reaches 85%.
What happens to the snapshot?

  • A. Snapshot deltas are allocated from the Reserved Capacity
  • B. Snapshot fails
  • C. Snapshot persists but new snapshot deltas cannot be created
  • D. Snapshot terminates

Answer: D

 

NEW QUESTION 46
A storage administrator uses Unisphere for PowerMax to provision new storage from a VMAX All Flash array. Which Workload Type is recommended for a combination of small and large block I/O workloads?

  • A. DSS
  • B. None
  • C. OLTP
  • D. Optimized

Answer: B

Explanation:
Reference https://docs.openstack.org/cinder/train/configuration/block-storage/drivers/dell-emc-powermax-driver.html

 

NEW QUESTION 47
How many hosts are supported by PowerPath and PowerPath/VE in the FX software package?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 48
What is the maximum number of front-end ports that can be configured on a PowerMax 8000?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 49
......